Due to age of current hydrogen generator, Tyndall National Institute needs to install two hydrogen generators capable of supplying hydrogen at a combined 8 m per hour at a minimum 225 psi. Systems should be capable of running independently or together. Generators must be capable of providing flow in the range of 0 m/hr to 8 m/hr, i.e. system must be able to handle flow dependent on demand. Minimum hydrogen quality: 99.9995. (Details of any systems that can improve on the quality should be included as an option.
Max H2O Vapour < 5 ppm, (Dew point -65#C/-85#F), N2 < 2 ppm, O2 < 1 ppm.
Generator must have E-Stop fitted. System must be able to send a signal to remote alarm. Remote shutdown must be included, i.e. on receipt of a signal from gas/fire detection. System must have appropriate IP rating. System, will be housed indoor in a non-hazardous, (non-classified) indoor plant room. System should include remote data collection and viewing of operational/alarm status option.
Deadline
The time limit for receipt of tenders was 2020-06-12.
The procurement was published on 2020-05-12.
Object Scope of the procurement
Title: UCC โ Two (2) Hydrogen Generators
LEE637C
Products/services: Laboratory, optical and precision equipments (excl. glasses)๐ฆ
Short description:
โDue to age of current hydrogen generator, Tyndall National Institute needs to install two hydrogen generators capable of supplying hydrogen at a combined 8...โ
Short description
Due to age of current hydrogen generator, Tyndall National Institute needs to install two hydrogen generators capable of supplying hydrogen at a combined 8 m per hour at a minimum 225 psi. Systems should be capable of running independently or together. Generators must be capable of providing flow in the range of 0 m/hr to 8 m/hr, i.e. system must be able to handle flow dependent on demand. Minimum hydrogen quality: 99.9995. (Details of any systems that can improve on the quality should be included as an option.
Max H2O Vapour < 5 ppm, (Dew point -65#C/-85#F), N2 < 2 ppm, O2 < 1 ppm.
Generator must have E-Stop fitted. System must be able to send a signal to remote alarm. Remote shutdown must be included, i.e. on receipt of a signal from gas/fire detection. System must have appropriate IP rating. System, will be housed indoor in a non-hazardous, (non-classified) indoor plant room. System should include remote data collection and viewing of operational/alarm status option.
Show more
Estimated value excluding VAT: EUR 1 200 000 ๐ฐ
Due to age of current hydrogen generator, Tyndall National Institute needs to install two Hydrogen generators capable of supplying hydrogen at a combined 8 m per hour at a minimum 225 psi. Systems should be capable of running independently or together. Generators must be capable of providing flow in the range of 0 m/hr to 8 m/hr, i.e. system must be able to handle flow dependent on demand. Minimum hydrogen quality: 99.9995. (Details of any systems that can improve on the quality should be included as an option.
Max H2O Vapour < 5 ppm, (Dew point -65#C/-85#F), N2 < 2 ppm, O2 < 1 ppm.
Generator must have E-Stop fitted. System must be able to send a signal to remote alarm. Remote shutdown must be included, i.e. on receipt of a signal from gas/fire detection. System must have appropriate IP rating. System, will be housed indoor in a non-hazardous, (non-classified) indoor plant room. System should include remote data collection and viewing of operational/alarm status option.
Show more Award criteria
Price is not the only award criterion and all criteria are stated only in the procurement documents
Scope of the procurement
Estimated total value excluding VAT: EUR 1 200 000 ๐ฐ
Duration of the contract, framework agreement or dynamic purchasing system
The time frame below is expressed in number of months.
Description
Duration: 12
Duration of the contract, framework agreement or dynamic purchasing system
This contract is subject to renewal โ Description
Description of renewals:
โThe contracting authority reserves the right to extend the term for a period or periods of up to [1 Year] with a maximum of [2] such extension or extensions...โ
Description of renewals
The contracting authority reserves the right to extend the term for a period or periods of up to [1 Year] with a maximum of [2] such extension or extensions on the same terms and conditions, subject to the contracting authorityโs obligations at law.
Legal, economic, financial and technical information Conditions for participation
List and brief description of conditions: Please see RFT document for further details.
Economic and financial standing
List and brief description of selection criteria: Please see RFT document for further details.
Conditions for participation
Please see RFT document for further details.
Technical and professional ability
List and brief description of selection criteria: Please see RFT document for further details.
Conditions for participation
Conditions for participation (technical and professional ability): Please see RFT document for further details.
Conditions related to the contract
Contract performance conditions: Please see RFT document for further details.
Procedure Type of procedure
Open procedure
Administrative information
Time limit for receipt of tenders or requests to participate: 2020-06-12
14:00 ๐
Languages in which tenders or requests to participate may be submitted: English ๐ฃ๏ธ
Conditions for opening of tenders: 2020-06-12
14:00 ๐
Complementary information Review body
Name: Office of the High Court
Postal address: Four Courts Ground Floor, Inns Quay
Postal town: Dublin 7
Country: Ireland ๐ฎ๐ช
Phone: +353 18886000๐
E-mail: highcourtcentraloffice@courts.ie๐ง
Source: OJS 2020/S 095-226461 (2020-05-12)
Contract award notice (2021-11-18) Contracting authority Name and addresses
Postal address: University of Limerick
Postal code: Co.Limerick
Information about joint procurement
The contract is awarded by a central purchasing body
Object Scope of the procurement
Title: UCC - Two (2) Hydrogen Generators
LEE637C
Short description:
โDue to age of current Hydrogen Generator, Tyndall National Institute needs to install 2 X Hydrogen generators capable of supplying hydrogen at a combined...โ
Short description
Due to age of current Hydrogen Generator, Tyndall National Institute needs to install 2 X Hydrogen generators capable of supplying hydrogen at a combined 8m3 per hour at a minimum 225psi. Systems should be capable of running independently or together. Generators must be capable of providing flow in the range of 0m3/hr to 8m3/hr, i.e. system must be able to handle flow dependant on demand. Minimum Hydrogen quality 99.9995. (Details of any systems that can improve on the quality should be included as an option.
Max H2O Vapour <5ppm, (Dew point -65๏ฐC/-85๏ฐF), N2 < 2ppm, O2<1ppm.
Generator must have E-Stop fitted. System must be able to send a signal to remote alarm. Remote shutdown must be included, i.e. on receipt of a signal from gas / fire detection. System must have appropriate IP rating. System, will be housed indoor in a non-hazardous, (non-classified) Indoor plant room. System should include remote data collection and viewing of operational / alarm status option
Show more Description
Description of the procurement:
โDue to age of current Hydrogen Generator, Tyndall National Institute needs to install 2 X Hydrogen generators capable of supplying hydrogen at a combined...โ
Description of the procurement
Due to age of current Hydrogen Generator, Tyndall National Institute needs to install 2 X Hydrogen generators capable of supplying hydrogen at a combined 8m3 per hour at a minimum 225psi. Systems should be capable of running independently or together. Generators must be capable of providing flow in the range of 0m3/hr to 8m3/hr, i.e. system must be able to handle flow dependant on demand. Minimum Hydrogen quality 99.9995. (Details of any systems that can improve on the quality should be included as an option.
Max H2O Vapour <5ppm, (Dew point -65๏ฐC/-85๏ฐF), N2 < 2ppm, O2<1ppm.
Generator must have E-Stop fitted. System must be able to send a signal to remote alarm. Remote shutdown must be included, i.e. on receipt of a signal from gas / fire detection. System must have appropriate IP rating. System, will be housed indoor in a non-hazardous, (non-classified) Indoor plant room. System should include remote data collection and viewing of operational / alarm status option
Show more Award criteria
Quality criterion (name): Technical
Quality criterion (weighting): 70%
Price (weighting): 30%
Description
Additional information: All information relating to tenders is published on www.etenders.gov.ie only
Procedure Administrative information
Previous publication concerning this procedure: 2020/S 095-226461
Award of contract
1๏ธโฃ
Contract Number: 1
Title: UCC - Two (2) Hydrogen Generators
Information on non-award
Other reasons (discontinuation of procedure)
Complementary information Review body
Postal town: Dublin
Postal code: 7
Source: OJS 2021/S 227-597392 (2021-11-18)